(1) If circuit breaker CB1 stays in the ON position, the vehicle cable assembly has a short
circuit. Set the power switch and CB1 to OFF; then reconnect the cable. Notify organizational
maintenance.
(2) If circuit breaker CB1 moves to the OFF position, set the power switch to OFF, reconnect
the cable and go to the next step.
Step 4.
Check for a short circuit in the smoke generator assembly.
a. Disconnect the cable assembly from connector 5J1 at the cover assembly of the smoke
generator (Figure 4-3).
Figure 4-3. Connector 5J1 at the smoke generator cover assembly
b. Set circuit breaker CB1 and the power switch to the ON position.
(1) If circuit breaker CB1 stays in the ON position, the smoke generator has a short circuit.
Set the power switch and CB1 to OFF; then reconnect the cable. Notify organizational maintenance.
(2) If circuit breaker CB1 moves to the OFF position, set the power switch to OFF; then
reconnect the cable and go to Step 5 for M1059 vehicles or skip to Step 6 for other vehicle applications.
4-5
CM3305