The CP-696/PDR-75 Reader capabilities are:
■ It measures from 0 to 999 cGy in any combination of neutron or GAMMA doses.
■ It indicates over-range doses with flashing digital panel meter display.
■ It is designed to nuclear survivability requirements for thermal flash and air blast, neutron
and GAMMA radiation fields, and Electro-magnetic Pulse (EMP).
■ It provides a single digital display reading in cGy for combined doses of neutron and
GAMMA radiation.
■ It operates from a power supply of either polarity.
The DT-236/PDR-75 Dosimeter capabilities are:
■ It measures from 0 to 999 cGy in any combination of neutron or GAMMA doses.
■ It is designed to nuclear survivability requirements for Neutron and GAMMA radiation fields
and EMP.
The performance data is:
■ Range is 0 to 999 cGy
■ Over range 1000 to 5000 cGy (DPM display flashes)
■ Operating Temperature is -26 to +125, F (-32 to +52 C)
■ Storage Temperature is -70 to +160 F (-57 to +71, C)
2-12
CM 2506